SFL 1 Sheath Fault Locator

Sheath Fault Locator

Sheath Fault Tester is a powerful system. It is an intact sheath of a plastic insulated medium, high or extra high voltage cable is the prerequisite for the avoidance of water ingress and subsequent cable faults. Different test can be carried using sheath fault locator. Sheath/earth faults is develop in any type of underground cable network such as low, medium, high voltage power cables or unshielded multi core control cables.

  • There manually selectable convince DC ranges for application
  • Cable and cable sheath testing up to 12 kV between metallic sheath / armoured and mass of earth.
  • Automatic sheath fault pre-location with high precision measuring bridge method.
  • Cable sheath fault pin pointing by pool of potential method.
  • Automatic discharging facility of cable under test, in case of power failure or after switching off.
  • Conversion of high-resistance faults in low-voltage cables.
  • Burn mode for conditioning the sheath fault.
  • It is extremely user friendly in obtaining the fault distance; it uses a micro-controller based fault distance calculator that enables the operator to get the pre-location measurements with precise accuracy.
  • Continues operation for extended period in case of pin-point difficult sheath faults.
  • Rugged construction and easy to carry on site.

Technical Specifications

Technical Specifications
Test Voltages 0-3, 0-6 & 0-12 kV DC continuously variable
Test Current 3 kV – 400 mA, 6 kV – 200 mA, 12 kV 100 mA DC
HV Range Selection Manual
Indication ON/OFF lamp indication, Analog moving coil meter for output voltage (kV) indication, Analog moving coil meter for output current (mA) indication, Over heat LED indication, Fault pre-location distance on LCD display & Sheath voltage drop indication on DPM
Pulse Ratio for Pin-pointing 1:3 second and 1:6 second selectable ON OFF time ratio
Cooling System Air Cooled
Fault Distance Calculator LCD display-16×2 characters with back light
DPM Power Supply 6V, 1.5Ah Rechargeable battery
Over Load Protection Mains Input current MCB switch in Live & Fast blow fuse in input mains supply.
Safety Protection Variac Zero inter-lock
Earth Discharge Output cable Plug inter-lock, HV Switch inter-lock & Over Heat Protection
Soft automatic discharge through in-built solenoid
Working Temp. 0°C – 55 °C
Storage Temp. – 5°C – 60°C
Dimensions 555 (L) x 355 (W) x 620 (H) mm + Handle 50mm + Wheel 65mm
Weight 70 Kg Approx
Sheath Fault Locator EFL 1
Meter 5-0-5uA
Sensitivity High & Low
Input resistance without amplifier 700 K Ohm
Input resistance with amplifier 100 K Ohm
Current Supply 1.5V x 8 Alkaline AA size cells
Dimensions 215 (L) x 200 (D) x 80 (H) mm
Weight 0.8 Kg Approx.